Go to optics-projects for viewing this category (click this caption)
This monochromator was developed as a combination of a DCM and a multilayer PGM in order to cover the whole available tender X-ray energy range of 1.5-10 keV at the MIFO beamline of the PTB at BESSY using one monochromator system only. Change of operation mode between PGM and DCM is automated and does not require venting of the system.
The hexapod units for the MIFO beamline of the PTB at BESSY feature the lastest updates of the hexapod design for compact size, straightforward alignment, and calibration at reliably excellent performance.
The constant-strut-length hexapod design used in this switching mirror unit is adapted from that of the EMIL beamlines hexapods (see projects P405 to P412).
This hard X-ray switching mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The mirror switching is realized by a vertical movement. The vacuum chamber accomodates not only the actual beam but also the passing…
This hard X-ray split mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The mirror splitting is realized by a vertical movement. The vacuum chamber accomodates not only the actual beam but also the passing…
This soft X-ray deflection mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The vacuum chamber accomodates not only the actual beam but also the passing soft and hard X-ray beams of the neighbouring branches.
This soft X-ray split mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The mirror splitting is realized by a vertical movement. The vacuum chamber accomodates not only the actual beam but also the passing…
This hard X-ray monochromator is part of the combined hard and soft X-ray EMIL beamlines at BESSY. The vacuum chamber accomodates not only the actual beam but also the passing soft X-ray beam. For DCM operation the hard X-ray beam passes without deflections through this monochromator. For PINK operation the hard X-ray beam either passes without deflection or is deflected…
This soft X-ray monochromator is part of the combined hard and soft X-ray EMIL beamlines at BESSY. The vacuum chamber accomodates not only the actual beam but also the passing hard X-ray and pink beams of the neighbouring branch. In all EMIL systems we integrated for the first time electrodes for carbon contamination prevention of the optical surfaces. In this…
We are using cookies and a few external resources. By using this website you agree our privacy policy.